For an efficient work zone, place the Velmix LQ controller, activator holder, bottles and POS screen close together. The user will frequently have to touch the screen while handling the bottles.
NOTE : Before you begin the installation, check the counter top thickness to ensure that the screws won't protrude through the top.
To install your Velmix LQ:
Firmly screw the controller and activator bracket (AZC-900036) to the underside of the counter top using the supplied screws (AZC-501035).
Connect the RS232 communication cable (AVP-002113) to the Veloce POS or the Ethernet cable (AVP-002118) to the network.
Plug the 120V cord into the power supply, then into the 120V outlet.
IMPORTANT! Do not alter the angle or bend the activator support, as Velmix automatically releases the plug (if programmed) when in the resting position. Bending the support may prevent this function from working properly.